Who needs to reference this guide?
Sites who need to input or modify settings on the wash menu of the Tunnel Master Jr. (TMJ) Tunnel Controller.
This guide is typically performed AFTER programming Outputs, Services, and Output Lists.
Overview
For more detailed information, please refer to the Set and Change TMJ Controller Settings Overview and the Tunnel Master Jr. Installation and User Manual.
Wash Settings
This Menu allows the user to set the various equipment settings that directly relate to their particular equipment. This is where the user will set many of the unique features of the Tunnel Master Jr. tunnel controller, such as the anti-theft and input substitution settings.
Wash Settings Example
|
1 |
From the main screen display, press the MENU button. |
[1] Bump Shift [4] View Counts [2] Wet Down Wash [5] Print Reports [3] Configure Wash |
|
2 |
From the numeric keypad, press the 3 key to select the Configure Wash option. |
[1] Services [4] Wash Settings [2] Outputs [5] Set Date Time [3] Outputs Lists [6] Set Password |
|
3 |
From the numeric keypad, press the numeric 4 key to select the Wash Settings menu option. |
EqptMeasurementInInches? _ _ _ _ _ |
|
4 |
Using the numeric keypad, press the 0 key to select Y for Yes or press the 0 key again for N for No. |
EqptMeasurementInInches?Y_ _ _ _ |
|
5 |
From the numeric keypad, press the F4 button to accept and save the entry. |
EqptMeasurementInInches?Y_ _ _ _ |
|
6 |
Press the F2 button to advance to the next setting to enter. |
PulseLength _ _ _ _ _ _ _ _ _ _ _ _ _ _ |
Critical Wash Settings
IMPORTANT: The following will list the most critical settings for proper Tunnel Controller operation. Refer to the TMJ User Manual for a full list of settings and their descriptions.
- Pulse Length: Needed for timing of all equipment
- Auto-Pulse: Useful in cases of Pulse Device failure
- Auto Gate: Useful in cases of Gate Device failure
- Roller Control: Needed for the controller to fire rollers from the keypad or remote roller button
- Input Device: Determines where washes are loaded for stacking purposes, this will be on K for keypad; unless you have a computer, in which case, this will be C for computer.
- Keypad 1 Address: Needs to be 5 for the primary entrance keypad to work for loading washes or sending the roller signal.